Queensland homes need photoelectric smoke alarms. The Queensland Fire Department says every home must have interconnected photoelectric alarms by 1 January 2027, and any alarm with an ionisation sensor should be replaced. A photoelectric alarm uses a light sensor to pick up smoke. An ionisation alarm uses a small radioactive source and an electrical current, and it no longer meets the Queensland requirement.
How does a photoelectric smoke alarm work?
Inside the chamber there’s a light source and a sensor set at an angle so the light normally misses it. When smoke drifts in, the particles scatter the light onto the sensor and the alarm sounds. The Queensland Fire Department describes it simply: photoelectric alarms detect smoke using a light sensor.
That suits the smouldering fires that start in a couch, a mattress or a pile of washing at night. They make plenty of visible smoke well before there’s a big flame.
How is an ionisation alarm different?
An ionisation alarm has a tiny radioactive source that charges the air in a chamber so a small current flows. Smoke disrupts that current and sets it off. They react well to fast, flaming fires. They’re also the ones that go off every time someone burns toast.
For Queensland homes the debate is settled. The fact sheet says to replace any alarm that contains an ionisation sensor.
How do I tell which type I’ve got?
Take a look at the label on the back or side of the alarm. You can twist most battery units off their base to read it. Look for:
- The word photoelectric or ionisation.
- A radiation symbol, which means ionisation.
- The Australian Standard code AS 3786-2014, which the Queensland Fire Department says to check for.
- A manufacture or expiry date.
If the alarm is hardwired, don’t pull it off the ceiling to read it. The wiring behind it is mains power. We can check it for you.
What else does a QLD smoke alarm need?
Type is one part of it. The QFD fact sheet lists three reasons to replace an alarm: it has an ionisation sensor, it isn’t interconnected, or it’s more than 10 years old. Interconnected means when one alarm sounds, they all sound.
Alarms also have to be in every bedroom, in every hallway or room connecting bedrooms, and on every storey. For the full room by room count, read how many smoke alarms you need in QLD.
Can I swap my old ionisation alarms myself?
It depends how they’re powered. The fact sheet says wireless alarms with a non-removable 10-year battery can be installed yourself. Hardwired alarms are connected to mains power and must be installed by a qualified electrician, and if your current alarms are hardwired, the replacements must also be hardwired.
In Queensland, anything touching the mains wiring is electrical work for a licensed electrician. More on that in do smoke alarms need to be hardwired in QLD.
Who can replace hardwired alarms on the peninsula?
Fins Up Electrical replaces ionisation and old hardwired alarms with interconnected photoelectric units across Redcliffe, Scarborough and out to Caboolture. Andrew checks how many the home needs, fits them and tests the whole set together. Free fixed quote before we start, licence 91921. See smoke alarm installation.
Want this sorted? Smoke alarm installation from Fins Up.
Licensed electrician, licence 91921. Free quote before any work starts. Open 24 hours Monday to Saturday.
Common questions
Are ionisation smoke alarms illegal in Queensland?
The Queensland Fire Department says to replace any smoke alarm that contains an ionisation sensor. Homes must have interconnected photoelectric alarms by 1 January 2027.
What standard should a QLD smoke alarm meet?
Look for AS 3786-2014 on the alarm. The Queensland Fire Department says that code shows it meets the new requirements.
Do photoelectric alarms go off less when cooking?
They tend to be less touchy about toast and frying than ionisation alarms, though steam and heavy cooking smoke can still set one off if it sits close to the kitchen.