By 1 January 2027, every home in Queensland must have photoelectric smoke alarms that meet AS 3786-2014, are interconnected, and sit in every bedroom, in the hallways connecting bedrooms to the rest of the home, and on every storey. Alarms must be hardwired or run on a 10-year non-removable battery, and anything over 10 years old has to go. Rentals and homes sold since 1 January 2022 already have to comply.

What does the 2027 smoke alarm law say?

Queensland brought in its smoke alarm changes in stages. New homes and major renovations came first, from 2017. Homes being sold or leased followed from 1 January 2022. The last stage covers everyone else. From 1 January 2027, every existing house, townhouse and unit has to meet the same standard, including owner-occupied homes nobody has sold or rented in years.

The Queensland Fire Department sums up the standard on its fact sheet. Each alarm must be:

  • Photoelectric. It detects smoke with a light sensor. Alarms with an ionisation sensor don’t count.
  • Built to AS 3786-2014. The standard code is printed on the alarm.
  • Interconnected. When one alarm sounds, they all sound.
  • Hardwired or on a 10-year non-removable battery. A clip-in 9 volt battery alarm doesn’t meet the rule.
  • Less than 10 years old and working when tested.

Where do the smoke alarms have to go?

The locations are set out in the regulation and repeated in the Fire Department’s guide:

  • In every bedroom.
  • In every hallway that connects bedrooms to the rest of the home.
  • If there’s no hallway, between the bedrooms and the other parts of that storey.
  • On every storey. If a storey has no bedrooms, at least one alarm goes on the most likely path out of the home.

Position matters too. Alarms go on the ceiling where practicable, and not within 300mm of a corner or a light fitting, or within 400mm of an air conditioning vent or ceiling fan blades. A typical three bedroom single storey home ends up with an alarm in each bedroom plus at least one in the hallway. Two storey homes and homes with bedrooms at opposite ends usually need more.

How do I know if my current alarms comply?

Take one down and check the back or the side. You’re looking for three things:

  • The words photoelectric, and AS 3786-2014.
  • A manufacture or expiry date. If it was made more than 10 years ago, it has to be replaced.
  • No ionisation sensor. Older alarms often carry a small radiation symbol. That’s an ionisation alarm and it has to go.

Then test whether they’re interconnected. Press the test button on one alarm. If the others don’t sound with it, they aren’t interconnected and don’t meet the 2027 rule. And count them against the list above. Plenty of older homes on the peninsula have one alarm in the hallway and nothing in the bedrooms.

Can I keep my hardwired alarms and add battery ones?

You can’t swap a hardwired alarm for a battery one. The Fire Department’s fact sheet is clear: if your current smoke alarms are hardwired, the replacements must also be hardwired. A hardwired alarm has to be installed by a licensed electrician.

What you can do is mix power types, as long as every alarm in the home is interconnected with every other one. Some hardwired alarms link to battery units by wireless, so an electrician can replace the existing hardwired ones and add sealed battery units in bedrooms that never had wiring. That can save running new cable through finished ceilings. See our guide on whether smoke alarms need to be hardwired for the detail.

What if I rent out or sell the property?

Then the 2027 date has already passed for you. Since 1 January 2022, a home must meet the full standard when a new lease starts, an existing lease is renewed, or the owner agrees to sell. Landlords also have to test and clean the alarms within 30 days before every new or renewed tenancy. We cover both in our guides on rental smoke alarm rules and selling a house in QLD.

Should I wait until late 2026 to sort it out?

We wouldn’t. Every owner-occupied home in the state has the same deadline, and electricians fill up in the last months before it. Alarm stock can run short too. Doing it now also means your family has working, linked alarms tonight, not in a year.

Fins Up Electrical installs and replaces photoelectric, interconnected smoke alarms across the Redcliffe peninsula and Moreton Bay. Andrew checks what you have, tells you what has to change, and gives you a free fixed quote before any work starts. Our licence number is 91921. More on our smoke alarm installation page.

Want this sorted? Smoke alarm installation from Fins Up.

Licensed electrician, licence 91921. Free quote before any work starts. Open 24 hours Monday to Saturday.

Common questions

When do Queensland homes have to comply with the new smoke alarm laws?

All existing homes must comply by 1 January 2027. Homes that were sold or leased, or had a lease renewed, since 1 January 2022 already need to comply.

Do smoke alarms in QLD have to be interconnected?

Yes. Every required smoke alarm in the home must be interconnected with every other one, so they all sound when one detects smoke.

Are ionisation smoke alarms still allowed in Queensland?

No. Compliant alarms must be photoelectric and must not contain an ionisation sensor.

Do I need a smoke alarm in every bedroom in QLD?

Yes. Queensland requires a smoke alarm in every bedroom, in hallways connecting bedrooms to the rest of the home, and on every storey.